What is oxygen deficiency?

Oxygen deficiency is an oxygen concentration in the air below what is needed to breathe safely; it can be detected only with an instrument, because it has no odor or color and the affected person's judgment deteriorates before they notice it.

What happens

Normal air contains about one fifth oxygen. When that proportion falls, the body receives less oxygen with each breath. The first organs to feel it are the brain and the heart. That is why the first symptoms are mental: loss of coordination, impaired judgment, euphoria or clumsiness. If the drop continues, loss of consciousness and death follow.

Why it is so treacherous

The body has no low-oxygen sensor. The feeling of breathlessness comes mainly from a buildup of carbon dioxide, not from a lack of oxygen. If the air lacks oxygen but does not contain excess carbon dioxide, the person may not feel short of breath. In addition, impaired judgment prevents them from recognizing the problem or deciding to leave. Many accidents are described this way: the person collapsed without having given any sign.

Where the deficiency comes from

  • Consumption: oxidation of metal (corrosion) in closed tanks, fermentation of organic matter and combustion consume oxygen.
  • Displacement: an inert gas such as nitrogen, argon or carbon dioxide enters the space and reduces the proportion of oxygen without changing the total pressure.
  • Absorption: certain materials, such as activated carbon or some sludges, retain oxygen.
  • Work: welding and cutting consume oxygen and can generate fumes.

A tank that has been closed for some time is a classic candidate: rust on the steel has consumed oxygen even if the tank has held nothing dangerous.

How it is managed

  1. Oxygen is measured before entry, from outside, with a calibrated instrument.
  2. The space is ventilated to renew the air, and then measured again.
  3. While people are inside, the detector keeps measuring and its alarm requires them to leave.
  4. If the space must remain without breathable air, entry is made with supplied-air respiratory protection.

What does not work

Lighting a match or leaning in to see if it “smells strange” is no use: both tests are unsafe. Nor is it correct to ventilate with pure oxygen to compensate, because excess oxygen creates a fire risk. Ventilation air must be breathable air.

Interpretation

A low reading is an instruction to act, not a curiosity: do not enter, or get out. Work in these spaces must be done by trained and authorized personnel, following the applicable regulations.

This guide is for information only. Work involving electrical risk, heights or hazardous atmospheres must be carried out by qualified and authorized personnel, following the applicable regulations.