What is a hazardous atmosphere?

A hazardous atmosphere is air in a space that can cause death, incapacitation, impairment of the ability to self-rescue, injury or acute illness through a lack or excess of oxygen, flammable gases or vapors, combustible dusts or toxic substances.

What defines it

The definition focuses on the effect on the person, not on a specific substance. An atmosphere is hazardous if it can kill, incapacitate, prevent a person from rescuing themselves or cause acute illness. What makes it so can be a shortage, an excess or the presence of contaminants.

The main categories

Abnormal oxygen

Lack of oxygen impairs judgment and consciousness without warning. Excess oxygen is not harmful to breathe in itself, but it makes materials, clothing and oils burn more intensely and more easily. That is why an oxygen value outside the normal range, in either direction, calls for attention.

Flammable gases and vapors

There is a risk when their concentration in the air enters the range in which they can ignite. A spark, an unsuitable tool or static electricity can be the ignition source.

Combustible dusts

Some dusts suspended in air, such as flour, sugar or fine metals, can burn or explode. They are associated with silos and hoppers. They are not detected by a gas detector.

Toxic substances

These are gases, vapors or fumes that cause harm through inhalation or contact, such as hydrogen sulfide or carbon monoxide. The harm depends on the concentration and the exposure time.

Where it comes from

  • Processes and residues of the space itself: fermentation, oxidation, stored products.
  • Work done inside: welding, painting, use of solvents, combustion engines.
  • Leaks from connected lines and inert gases used for purging.
  • Ingress from outside through openings, drains or soil.

Why the senses cannot be trusted

Many hazards have no odor or color, and some, such as hydrogen sulfide, deaden the sense of smell as the concentration rises. Lack of oxygen does not produce a clear warning either. The only reliable way to know the atmosphere is to measure it with calibrated, working instruments.

When to measure

Before entering, from outside; on entering, at different levels; and continuously while inside, because the atmosphere changes with the work. If a reading falls outside acceptable limits, the consequence is to leave, not to keep working. Assessment and entry must be done by trained and authorized people, in accordance with the applicable regulations.

This guide is for information only. Work involving electrical risk, heights or hazardous atmospheres must be carried out by qualified and authorized personnel, following the applicable regulations.