Definition
When a current passes through the arm, the muscles that close the hand and those that open it contract at the same time. The flexors are stronger, so the hand closes on the object. Let-go current, also called release current, is the maximum value at which the person can still overcome that contraction. Beyond it, they remain gripping the conductor, unable to let go.
Why it is so important
Electric shock injury depends on the magnitude of the current and on how long it flows. A current that is not enough to cause fibrillation can become dangerous if the person cannot let go, because the time is extended: burns, fatigue, difficulty breathing when the current crosses the chest, and the likelihood of a more serious shock all increase.
Where it sits among the thresholds
| Threshold | What happens |
|---|---|
| Perception | The person feels the current but can withdraw without difficulty. |
| Let-go | Involuntary contraction; the person cannot open their hand. |
| Respiratory difficulty | Contraction of the chest muscles. |
| Ventricular fibrillation | The heart loses its coordinated rhythm; this is the most frequent cause of death. |
The values of each threshold vary with the person, the frequency, the current path and the duration, so they are handled as statistical ranges rather than as a fixed number.
Factors that change it
- Frequency: alternating current at power line frequencies is particularly effective at causing muscle tetany.
- Person: it varies with muscle mass, sex, age and physical condition.
- Contact surface: a firm grip on a conductor with a large surface makes release harder.
- Moisture: wet skin lowers resistance and increases the current for the same voltage.
What it means for design and work
This property explains why it is not enough to trust that someone will pull away on their own. It is prevented by eliminating the possibility of contact: insulation, barriers, de-energized work and residual current protective devices, which disconnect before the exposure time becomes critical in low-voltage circuits. If someone is stuck to a conductor, they must not be touched until the power has been cut. Work on installations is the responsibility of qualified personnel.