What does NOM-029-STPS require?

NOM-029-STPS sets safety conditions for maintenance activities on electrical installations in workplaces, in order to prevent risks to workers; its exact scope must be checked in the current edition.

What it covers

NOM-029-STPS is a Mexican official standard issued by the labor authority. It deals with safety during maintenance activities on electrical installations in workplaces. Its purpose is to prevent the shock, arc and other hazards faced by those who work on these installations.

General scope

It applies to workplaces where maintenance is carried out on permanent or temporary electrical installations. It focuses on the employer’s responsibilities and the workers’ obligations in this activity.

Topics it normally addresses

  • Assessment and inspection of the installations: knowing their condition and safety status.
  • Safety procedures: for maintenance, including both energized and de-energized tasks.
  • Energy control: lockout and tagout, and verification of the absence of voltage.
  • Protective equipment and tools suited to the risk.
  • Personnel: training, authorization and qualification to perform the tasks.
  • Signage and records: documentation of the work done.
  • Oversight: supervision and an emergency response plan.

What this means in day-to-day work

An engineer will see that electrical maintenance work is planned in writing, that personnel are authorized for specific tasks, that isolation and verification are performed before any work starts, and that there is documentary evidence. Inspections by the authority review that file and whether what is written matches what happens in the field.

When meeting the minimum is not enough

An official standard sets the legal floor, not the technical ceiling. In complex installations, it may be necessary to supplement it with risk studies, arc flash studies and more detailed recognized practices.

How to consult it

Official standards are updated, amended or replaced. Before applying it, consult the current edition in the Diario Oficial de la Federación or the labor authority’s official source, and confirm its scope, definitions and deadlines. This guide is for orientation only.

Electrical work must be done by qualified personnel, following the applicable regulations.