What happens in an arc
In a fraction of a second, an electric arc releases an enormous amount of energy in the form of radiant heat, intense light, ultraviolet radiation, pressure and molten metal spatter. The face and eyes are especially vulnerable areas, with tissue that is damaged by brief exposures.
How the face shield works
- Shield: made of a transparent material that reduces the transmission of infrared and ultraviolet radiation and that does not melt or drip onto the skin. Its rating is expressed in terms of the energy it withstands before allowing burns.
- Impact resistance: it stops particles and fragments thrown by the explosion.
- Coverage: it must cover the forehead, face and sides, and the right design adds protection for the chin and neck.
- Support: a compatible headgear or hard hat keeps it in position, so that it is not displaced by the impact.
How it relates to the rest of the protection
The face shield is one component of a system. It is used with a hard hat, safety glasses underneath, arc-rated clothing, gloves and appropriate footwear. If one is missing, overall protection falls to the level of the weakest item. The neck and lower face are often left exposed by a simple face shield, so an arc-rated balaclava or a full hood is used, depending on the energy level.
What the user sees in practice
- A slight tint that reduces light and can affect reading in dark environments.
- Scratches and cloudiness with use, which reduce visibility and protection.
- Possible fogging, which is dealt with using treatments or ventilation without compromising coverage.
Care and limits
- Clean it with products recommended by the manufacturer; solvents damage the shield.
- Inspect it before each use and replace it if there are cracks, deep scratches or deformation.
- Select it with a rating sufficient for the incident energy from the study.
No face shield makes a task safe on its own. This work must be carried out by qualified personnel following the applicable regulations.