How is PPE inspected before use?

Personal protective equipment is inspected before each use by comparing its condition with what its function demands: look for visible damage, contamination, deformation or expired service life, and remove anything doubtful from service.

The principle

PPE is the last barrier: if it fails, there is no other. That is why it is inspected every time, not only during periodic reviews. The inspection looks for any damage that reduces protection, and when in doubt the equipment is not used.

General method

  1. Check identification and validity: markings and test or manufacturing date, where applicable.
  2. Inspect visually in good lighting, on both sides.
  3. Inspect by touch: run a hand over the item, feeling for areas that are hard, sticky, bulging or different in texture.
  4. Check the fit and the fastenings.
  5. Record the result according to the company’s system and remove anything that does not comply.

What to look for by type

  • Dielectric gloves: cuts, punctures, cracks, blisters, hardening, deformation and contamination with oil or chemicals. An inflation test is performed to detect air leaks, following the manufacturer’s instructions.
  • Hard hats: cracks, dents, discoloration, deterioration of the inner suspension. A hard hat that has taken a severe impact is replaced.
  • Face shields and visors: scratches, cloudiness, cracks, damaged frames and loose mounts.
  • Arc-rated clothing: holes, worn seams, grease or fuel stains, damaged fasteners and laundering that does not follow the manufacturer’s instructions.
  • Footwear: detached soles, punctures, exposed metal parts.
  • Harnesses and lifelines: fraying, cuts, burns, deformed hardware.

Criteria for removal

Remove any item with damage that reaches the protective layers, contamination that cannot be eliminated according to the manufacturer, deformation, expired validity or illegible identification. It is marked and set apart so that nobody else uses it by mistake.

What to check first

Start with what is closest to the skin and to the source of risk: gloves and face shield for work with electrical risk. Remember that visual inspection does not replace the periodic tests required for that type of equipment. Work involving electrical risk must be carried out by qualified personnel in accordance with the applicable regulations.