What effects does electric current have on the human body?

The effects of current on the body depend on its magnitude, how long it flows, its path and whether it is direct or alternating; voltage matters only because, together with the body's resistance, it determines that current.

The damage depends on current, not only on voltage

What passes through tissue is current. The touch voltage, divided by the total resistance of the path (skin, internal tissue, footwear, the surface being stood on), gives the resulting current. That is why the same voltage can be almost harmless with dry, calloused skin and dangerous with wet skin or a wound.

Factors that determine severity

  • Magnitude of the current: the higher the current, the more severe the effects.
  • Duration: a moderate current over a long time can be more harmful than a higher one for an instant.
  • Path: a path that crosses the chest (hand to hand, hand to foot) compromises the heart and breathing; a path localized in a finger is different.
  • Type of current and frequency: alternating current at power frequency is particularly dangerous for the heart rhythm.
  • Contact conditions: moisture, contact surface and pressure change the resistance.

Effects in increasing order of severity

  1. Perception: mild tingling, with no direct risk, but it can cause a startled movement and a secondary fall.
  2. Involuntary muscle contraction: the muscles contract and the person cannot let go of the conductor. This is the so-called let-go threshold, and it explains why someone can end up “stuck” to the source.
  3. Breathing difficulty: contraction of the chest muscles can prevent breathing for as long as the current flows.
  4. Ventricular fibrillation: the heart loses its coordinated rhythm and stops pumping blood effectively. This is the main cause of death by electrocution and requires immediate emergency medical care.
  5. Cardiac arrest and neurological damage in intense exposures.

Thermal and secondary effects

Besides the effect on the nervous system and the heart, current generates heat through the Joule effect. This produces burns at the entry and exit points, and damage to deep tissue that is not always visible from outside. Injuries can appear hours later, so a person who has received a shock must have a medical evaluation even if they look fine.

Secondary injuries are also common: falls from height due to being startled, blows and burns from the arc flash that can accompany the shock.

What it means in practice

Protective equipment and disconnecting devices seek to limit the current or the time, because those are the two variables that weigh most. Even so, work on energized installations or with electrical risk must be done by qualified personnel, following the applicable regulations.