Definition
An ordinary spectrum is a snapshot: it shows which frequencies are present at one instant. A waterfall gathers many spectra taken one after another and arranges them in layers, with frequency on one axis, amplitude on another and a third variable, time or speed, on the remaining one. It resembles a waterfall of lines because each spectrum sits behind the previous one.
Two main uses
- Waterfall versus speed: built during a startup or shutdown. It shows which components follow speed (they appear as sloping lines, which are the orders) and which stay at a fixed frequency (vertical lines, typical of resonances).
- Waterfall versus time: gathers measurements taken over hours, days or months to visualize trends in the spectral content.
What you learn from reading it
- Resonances of a structure appear as ridges at a fixed frequency, which the order lines approach when the speed coincides with them.
- Critical speeds are located where the first-order line crosses a resonance with an increase in amplitude.
- New peaks appearing in the most recent layers indicate that a new component is emerging.
- Non-synchronous components, such as those from oil whirl, do not follow the order lines.
How to interpret the result
The waterfall separates phenomena that are confused in a single spectrum: a peak may be tied to speed or to a resonance, and only the variation between layers reveals which. Care must be taken with the scale (linear or logarithmic) and the calculation parameters, because they affect the appearance of the plot.
When it does not apply
With a machine that always operates at constant speed, a waterfall versus speed provides no information; one versus time is still useful for seeing gradual changes.