Definition
A rotor supported on bearings is an elastic system with its own natural frequencies. When the rotational speed, expressed as a frequency, coincides with one of them, the excitation from residual unbalance, which occurs once per revolution, amplifies the response. That speed is called the critical speed. It is not a defect in itself, but a property of the rotor-support system.
What it depends on
- The stiffness of the shaft and supports: more stiffness raises the critical speed.
- The mass and its distribution along the rotor: more mass lowers it.
- The damping of the bearings, which limits the amplitude peak.
In the supports, stiffness and damping change with speed and with the oil film, so the effective critical speed can vary from the theoretical value.
What is seen in a startup or shutdown
- The vibration amplitude rises to a maximum as the rotor passes through the critical speed and then falls.
- The phase changes noticeably when crossing it; in a rotor with unbalance, the typical phase shift is about half a revolution between before and after the resonance.
These behaviors are displayed in plots of amplitude and phase versus speed, known as Bode plots, and in waterfall plots.
What it means for operation
Sustained operation near a critical speed is undesirable because any unbalance produces high vibration. Machines are designed to operate with a separation margin from their critical speeds, or to cross them quickly during startup. A rigid rotor operates below its first critical speed; a flexible one operates above one or more.
When it is mistaken for something else
A resonance of the structure or the base can look like a rotor critical speed. To tell them apart, impact tests are used or the behavior is compared with speed and with other conditions.