Basic idea
Each time a ball rolls over a crack or spall on a raceway, it produces a small impact. If the defect is on the raceway, the impacts repeat at the frequency at which the balls pass over it. That frequency depends on the bearing geometry and the rotational speed, not on the size of the defect.
The two main frequencies
With N rolling elements, shaft rotational speed f, rolling element diameter d, pitch diameter D and contact angle θ, the usual expressions are:
- Outer race (BPFO): N/2 · f · (1 − (d/D) · cos θ)
- Inner race (BPFI): N/2 · f · (1 + (d/D) · cos θ)
The sum of the two equals N times f, which serves as a check. In both cases, the frequency is not an integer multiple of the rotational speed, and that is the key to recognizing it in a spectrum.
What is seen in the spectrum
- An outer race defect produces a peak at BPFO and its harmonics, normally without marked sidebands, because the outer race is usually fixed relative to the load.
- An inner race defect produces BPFI with sidebands spaced at the rotational frequency, because the defect enters and leaves the load zone on each revolution.
- In early stages, the conventional vibration spectrum may show nothing, and the defect is better revealed by envelope demodulation or at high frequencies.
Where the data come from
The manufacturer usually publishes the bearing fault factors, and many analysis programs have databases of models. If they are not available, they can be calculated with the formulas above and the bearing dimensions.
Common mistakes
- Expecting an exact match: ball slip makes the actual frequencies deviate slightly from the calculated ones.
- Using the nominal speed instead of the measured speed, especially on equipment with a variable frequency drive.
- Confusing BPFO with a gear or belt frequency.
- Taking an isolated peak as a diagnosis without reviewing harmonics, trend and other indicators such as temperature and noise.
- Forgetting that a new bearing with inadequate lubrication can also generate broadband peaks.