How is vibration monitored in a centrifugal pump?

Vibration in a centrifugal pump is monitored by measuring at the motor and pump bearings, in the radial and axial directions, on a fixed routine and with the machine in comparable operating conditions, in order to watch the trend and detect faults.

What is monitored and why

A centrifugal pump combines mechanical parts (bearings, coupling, rotor) and hydraulic phenomena (flow, pressure). Each fault leaves a different signature in the vibration, and monitoring seeks to detect it before it forces the process to stop.

Points and measurements

  • Motor and pump bearings, in the horizontal, vertical and axial directions.
  • Velocity for general severity; acceleration or envelope for bearings.
  • A record of the conditions: flow, pressure and speed.

Typical faults and their signal

  • Unbalance: peak at once per revolution.
  • Misalignment: one and two times running speed, with an axial component.
  • Bearings: characteristic frequencies and high-frequency noise.
  • Cavitation: broadband energy and noise.
  • Hydraulic effects: components at the vane pass frequency and its harmonics, which increase when the flow is far from the design point.
  • Looseness: multiple harmonics of running speed.

Operating conditions

Hydraulic behavior changes with flow, so measurements must be taken under comparable conditions. A pump operating with the valve almost closed may vibrate more without any mechanical deterioration.

How to interpret the trend

A gradual increase in a specific band indicates a developing defect. A sudden change after a process modification points to a hydraulic or operational cause. Levels are compared with the machine’s own baseline and with the applicable evaluation criteria.

What to check first

When vibration increases, the process conditions are checked first: flow, suction pressure and valve positions. If there are no changes, the base tightening, the condition of the coupling and the bearings are checked. This sequence avoids intervening on a pump that has a hydraulic problem.