General scope
ISO 13373-1 is the general part of a series devoted to machine condition monitoring and diagnostics using vibration. It describes general procedures and good practices, and other parts of the series develop more specific topics. It does not set acceptance limits: it guides the process.
What topics it organizes
- Program objectives: what is to be detected and what decisions will be made with the data.
- Selection of measurements: quantities, points, directions and frequency bands, according to the machine and its failure modes.
- Transducers and mounting: criteria to make the signal representative and repeatable.
- Acquisition: operating conditions, measurement frequency and instrument parameters.
- Data management: recording, trends and traceability.
The underlying idea
A monitoring program is only as good as its data. One data point is comparable with another only if both were taken at the same point, with the same method and under similar operating conditions. The guide insists on defining and documenting these conditions so that the observed changes are due to the machine and not to the method.
How it is used with other standards
- Severity criteria come from other standards, such as those on evaluating machine vibration.
- Personnel competence is addressed in qualification standards.
Consultation
The standard is a guidance document. To apply it to a specific program, the current edition must be consulted and adapted to the machine and its failure modes.
How to interpret the result
Once the program is running, review whether the measurements really support the decision they were designed for. If a measurement never changes a decision, or if a relevant failure mode has no measurement watching it, the program must be adjusted. The guide favors this periodic review.