24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What does ISO 18436-2 cover on analyst certification?

ISO 18436-2 defines the competence requirements and the assessment and certification criteria for personnel who perform machine condition monitoring and diagnostics using vibration, organized in categories according to level of responsibility.

General scope

The standard sets the requirements for qualifying and assessing the people who perform condition monitoring and diagnostics using vibration. It is not about how to measure vibration, but about who is in a position to do so and to interpret it, and how that competence is demonstrated.

What it includes

  • Competence categories: levels with increasing responsibilities, from data collection to advanced diagnostics and running a program.
  • Knowledge requirements: topics such as vibration fundamentals, data acquisition, signal analysis and fault diagnosis.
  • Experience and training: a practical track record consistent with the level is expected.
  • Examination: a written assessment and verification of experience by a certification body.

Why it matters

The result of a vibration analysis depends on the person who decides where to measure, how to configure the instrument and how to interpret the spectrum. Two analysts at different levels may reach different conclusions from the same data. A competence standard seeks to make diagnosis consistent and the level of the person issuing it verifiable.

What it is not

  • It is not a measurement method or a severity criterion.
  • Certification is granted by a certification body, not by the standard.
  • A certificate does not replace judgment or experience with the specific machine.

When to consult it

When defining personnel requirements for a monitoring program or when contracting diagnostic services. The current edition and the requirements of the certification body must be consulted.

How to interpret the result

When reviewing a diagnostic report, it is worth asking what category the signatory holds and on what types of machines that person has experience. A basic-level analyst can collect data reliably, and a higher level is the appropriate one for issuing complex diagnoses and defining actions.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer