What does the ISO 20816 series set out for machine vibration?

The ISO 20816 series sets out how to measure and evaluate the mechanical vibration of machines, with parts for different machine types, and defines the quantities, the measurement positions and the criteria used to classify vibration condition.

General scope

The ISO 20816 series covers the measurement and evaluation of the mechanical vibration of machines. It is organized in parts: a general part with the common principles and others specific to machine families, such as industrial rotating machines, turbine sets or generating equipment. Taken together, it replaces earlier standards that treated measurement on the casing and on the shafts separately.

What it defines

  • The quantities to be measured and how they are expressed.
  • Where and in which directions the transducer is placed.
  • The operating conditions during measurement.
  • A classification criterion based on condition zones, ranging from machines in good condition to others in which the vibration may cause damage.

How the evaluation is used

The criterion is based on the magnitude of the vibration and on how it evolves over time. Changes from a stable reference value for the machine itself are as important as the absolute value, because a large variation can signal a problem even if the level remains in an acceptable zone.

What it does not do

  • It does not diagnose the cause of the vibration; it only classifies its severity.
  • It does not replace the manufacturer’s recommendations or the contractual limits of a specific machine.
  • It does not cover every type of machine; each part has its own scope of application.

How to consult the standard

Before applying a criterion, identify which part applies to the machine and consult the current edition, since the parts have been updated over time and the criteria and limits change between editions.

An example of use

A maintenance team measures vibration velocity at the supports of a motor and a pump, compares it with the evaluation zone for that type of machine and records the measurement as a baseline. If the value changes noticeably months later, the change is treated as an alert even if the zone has not changed.