Stud, adhesive or magnet mounting?

A stud gives the stiffest attachment and the widest frequency band, adhesive is a good alternative when drilling is not possible, and a magnet is the most practical option but limits the usable range at high frequencies.

Why mounting matters

The sensor and its attachment to the surface form a mass-spring system. The stiffness of the attachment determines the frequency at which the mounted resonance appears. A soft mount lowers that resonance and narrows the band in which the reading is faithful, and it also artificially amplifies signals close to the resonance.

Screw or stud

  • This is the stiffest mount and the one that offers the greatest bandwidth.
  • It requires a flat surface and a tapped hole.
  • It is preferred for permanent monitoring and for tests where high-frequency accuracy is critical.
  • The tightening torque recommended by the manufacturer must be observed.

Adhesive

  • Useful when the part cannot be drilled or the sensor is light.
  • Its performance depends on the type of adhesive, the thickness of the layer and the surface preparation.
  • A thick or soft layer reduces the bandwidth.
  • Removal can leave residue and must be done carefully.

Magnet

  • Quick to place on ferromagnetic surfaces, ideal for routes.
  • The mounted resonance is lower than with a stud.
  • A rough, painted or curved surface, or a weak magnet, degrades performance.
  • It depends on the operator placing the sensor in the same way every time.

How to choose

Ask what maximum frequency is of interest, how permanent the measurement is and how repeatable it must be. For high-frequency defects, a stud or rigid adhesive is preferred. For general severity monitoring on routes, a well-placed magnet is usually sufficient. In any case, the method must be the same for every measurement so that trends are comparable.