A MEMS accelerometer is an acceleration sensor made of silicon with a microscopic structure that deflects under acceleration, and it measures that deflection electrically, generally through a change in capacitance, with a response down to zero frequency.

How it works

MEMS stands for microelectromechanical system. A tiny silicon mass is suspended by microscopic springs. When the sensor accelerates, the mass moves relative to the frame and the capacitance between fixed and moving plates changes. A circuit integrated in the same package converts that variation into an analog or digital signal.

What sets it apart from the piezoelectric type

  • It responds to constant acceleration: it measures from zero frequency, so it detects tilt (gravity is an acceleration) and very slow movements.
  • Small size, low power consumption and low cost: these make it suitable for wireless sensors and for portable or embedded equipment.
  • Digital output is common: with an integrated converter, it simplifies the instrumentation.

Limitations

  • In many models, the bandwidth and noise level are less favorable for detecting high-frequency defects, such as incipient bearing defects.
  • The measurement range may be lower than that of the piezoelectric sensors used for strong shocks.
  • Thermal drift and zero offset require compensation.

Where it fits

It works well for measuring low- and medium-frequency vibration, for assessing the movement of structures and for providing more economical condition monitoring at many points. For detailed high-frequency diagnostics, the piezoelectric type is usually more suitable.

How to choose

Compare the required frequency band, the noise level against the expected amplitudes, the range and the environmental conditions. Specifications must be taken from the data sheet of the model in question.

What to check first

Before using a MEMS sensor for machinery monitoring, check the frequency band and the sensor’s own noise against the expected levels, since a sensor with a good range but high noise may not distinguish small changes. Also check how it is attached to the surface, because the mounting limits its response as well.