The physical principle
Certain materials produce an electric charge when they are deformed. Inside the sensor, a small mass rests on the piezoelectric element. When the housing accelerates, the mass tends to lag behind because of inertia and compresses or shears the element with a force equal to mass times acceleration. The resulting charge is therefore proportional to the acceleration.
Two ways of delivering the signal
- Charge mode: the sensor delivers charge and requires an external charge amplifier. It withstands high temperatures because it has no internal electronics.
- Integrated electronics (IEPE type): it incorporates an internal conditioner and is powered with a constant current through the same cable. It is the most widely used in the field because of its simplicity.
What determines its behavior
- Sensitivity: the relationship between the signal and the acceleration. A more sensitive sensor detects low levels but tends to be heavier.
- Frequency response: it is flat between a lower and an upper limit; toward the top, the sensor’s own resonance appears and limits the usable band.
- Mass: a sensor that is too heavy changes the dynamics of a light structure.
What the engineer sees
It does not measure very low frequency components well, and it does not measure constant acceleration, because the charge dissipates over time. Shocks, moisture in the connector, damaged cables and ground loops show up as noise, drift or jumps in the signal. Flexible mountings reduce the real bandwidth.
When it does not apply
For near-static or very low frequency motion, a capacitive or MEMS accelerometer is more suitable.
What to check first
When faced with a strange signal, check the connector and cable before suspecting the sensor, confirm that the constant-current supply is correct and test the sensor with a vibration calibrator. An out-of-range bias, cable noise from movement or moisture explain most doubtful readings.