Natural frequency
Any structure with mass and stiffness tends to oscillate at its own frequencies when it is struck and left free. In the simple model of a mass on a spring, the natural frequency increases with stiffness and decreases with mass; it is proportional to the square root of the ratio of stiffness to mass. Real structures have many natural frequencies, each with its own deformation shape.
Resonance
If a periodic force, such as that from rotor unbalance, has a frequency close to a natural frequency, the response is amplified. The amplification is limited by damping: the lower the damping, the higher the peak. Near resonance, the phase of the response also changes markedly, shifting by about half a turn when passing through it.
What is observed on a machine
- Vibration rises sharply within a narrow speed range and falls on either side.
- A small change in speed changes the amplitude considerably.
- A “healthy” machine vibrates excessively with no evident mechanical cause, and improves when the speed or the support stiffness is changed.
- During startup or shutdown, a critical speed is crossed and a peak and a phase change are seen.
How to tell it from a defect
A mechanical defect produces vibration that follows the rotating speed in a more or less regular proportion. Resonance produces a peak that does not move when the excitation is varied: the natural frequency is a property of the structure. A bump test or a speed sweep can confirm this.
What to do about it
- Change the stiffness or the mass to shift the natural frequency away from the excitation frequencies.
- Increase the damping.
- Change the operating speed to avoid the critical zone.
- Reduce the exciting force, for example by improving the balance.
Structural modifications must be validated, because they shift one resonance and may bring another one closer.