What is mechanical vibration and what quantities describe it?

It is the oscillatory motion of a machine or structure about an equilibrium position; it is described by its amplitude, frequency and phase, and the amplitude can be expressed as displacement, velocity or acceleration.

Definition

A machine vibrates when its parts oscillate about a rest position. Every rotating machine vibrates to some degree, because no rotor is perfect; what matters is how much, at what frequencies and how this changes over time. A change in the pattern usually signals a change in mechanical condition.

The three characteristics of the signal

  • Amplitude: the intensity of the motion.
  • Frequency: how many times per second the cycle repeats. It identifies the source, because each mechanical phenomenon has associated frequencies.
  • Phase: the offset of the oscillation relative to a reference or to another point.

Displacement, velocity and acceleration

The motion can be described by how far it moves (displacement), how fast (velocity) or how quickly that velocity changes (acceleration). These quantities are related: velocity is the derivative of displacement and acceleration is the derivative of velocity. For a sinusoidal vibration of angular frequency ω, the velocity amplitude is ω times the displacement amplitude, and the acceleration amplitude is ω times the velocity amplitude.

This has a practical consequence: displacement emphasizes low frequencies, acceleration emphasizes high frequencies, and velocity sits in between. For this reason:

  • Displacement is used for slow or large movements, as in turbomachinery shafts.
  • Velocity is commonly used to assess overall vibration severity in industrial machines.
  • Acceleration is suited to high frequencies, such as those of gears and bearings.

Amplitude values

The same signal can be expressed as a peak, peak-to-peak or RMS value. For a sine wave, the peak-to-peak value is twice the peak, and the RMS value is the peak divided by the square root of two. When comparing measurements, use the same type of value and the same units.

What an engineer sees

An instrument shows an overall value and a spectrum. The overall value indicates how much vibration there is, and the spectrum reveals where it comes from.