Definition
The camera measures radiation and converts it into temperature. To display it, the camera assigns a color to each value. That assignment is the palette. Each pixel keeps the same data whatever the palette: changing it is like changing a graph’s color map, not the numbers.
Common types
- Grayscale: shades vary from dark to light with temperature. It highlights shapes and details without the distraction of color.
- Ironbow or smooth-transition rainbow: spreads color progressively and is common for inspection.
- Rainbow with many colors: distinguishes more steps, but can create apparent boundaries where there are none.
- High-contrast palettes: highlight the maximum or minimum; useful for alarms or searching for extremes.
How it affects the reading
The eye perceives color jumps as abrupt changes. If the palette changes color quickly over a narrow interval, a small temperature difference looks large. In grayscale, the same jump looks gentle. That is why the palette influences how severity is perceived, even though it does not change the data.
How to choose it
- For seeing patterns and geometry: grayscale or a smooth palette.
- For locating an extreme point: a palette with contrast at the extreme.
- For reports: a palette that stays constant between inspections and a visible scale bar with its values.
- For people who have difficulty distinguishing colors: a grayscale palette or one with a monotonic variation in luminance.
A point that gets overlooked
A thermal image without a scale cannot be interpreted. The palette must be accompanied by the scale and by the minimum and maximum values with which it was displayed. Changing the palette does not correct a bad measurement: an emissivity error looks the same in any color.