What is really being measured
The refractory is an insulator that protects the steel shell from process temperatures. The camera does not see the refractory, but the outer surface. The principle is heat flow: if the refractory thins or cracks, its thermal resistance falls, more heat passes outward, and the shell temperature rises in that area.
What patterns appear
- Localized hot patch: wear or loss of lining at one point.
- Hot line or band: possible open joint or crack.
- Broad, gradual hot area: general wear or degraded insulation.
- Cold area within a hot area: buildup of adhered material or an inner crust, which insulates.
What to watch for when interpreting
- The emissivity of an oxidized or painted shell differs from that of clean steel and can vary from one area to another.
- Operating status matters: process temperature, equipment cycle, and load change the thermal map.
- Reflections from hotter nearby areas can be mistaken for hot spots.
- Sun and moving air affect the outer surface.
- Structures, supports, and stiffeners alter the local pattern and are not always defects.
From temperature to diagnosis
The image does not give the remaining thickness. Estimating it requires a heat transfer model with design data (materials, original thickness, interior temperature), and the estimate must be checked against other evidence such as direct measurements during shutdowns or visual inspection. The most reliable value of the technique is the trend: an area that holds its temperature across successive inspections is very different from one that is rising.
How it is recorded
Use the same capture position, note the operating status, and keep the baseline images taken after reinforcement or repair of the lining. Access to hot equipment involves burn and gas hazards and must be undertaken only by qualified, authorized personnel in accordance with plant procedures.