A tiny thermometer per pixel
The microbolometer is the detector in most general-purpose thermal cameras. It is an array of thousands of elements, each of which works as a microscopic resistance thermometer.
How it works
- The pixel is a very thin membrane suspended above the readout circuit, attached only by fine supports, so that it loses almost no heat to the substrate.
- Infrared radiation reaching the pixel is absorbed and heats the membrane by a fraction of a degree.
- The membrane material, such as vanadium oxide or amorphous silicon, changes its electrical resistance with temperature.
- The readout circuit measures that change and converts it into a signal value for each pixel.
- The processor transforms it into temperature using the calibration.
The assembly is vacuum-packaged so that air does not conduct heat and reduce sensitivity.
Advantages and limitations
- No cryogenic cooling: the sensor is stabilized at a working temperature, which results in equipment that is compact, consumes less power and costs less than cooled-detector units.
- Long-wave band: this is the region where these detectors respond best for ordinary temperatures.
- Slower response: because they are thermal, they need to heat up and cool down, so they follow very fast events less well than a photon detector.
- Drift: the signal from each pixel changes with the camera temperature, so periodic correction is required.
What an engineer sees in practice
The “click” heard from time to time in the camera is the internal shutter closing to present a uniform reference and readjust the differences between pixels. During that instant the image freezes. It is advisable to let the camera stabilize when it is switched on, especially if it has moved from one environment to another at a very different temperature.
How to interpret the figure
Sensitivity is summarized by the NETD, and spatial resolution by the number of pixels and the instantaneous field of view.