How is active thermography performed?

Active thermography applies an external thermal stimulus to the object and observes how its surface responds; internal defects alter the heat flow and show up as areas with different behavior.

Difference from passive thermography

In passive thermography, you observe the heat the object produces by itself, as in a connector under load. In active thermography, energy is introduced from outside, because the object is at a uniform temperature and shows nothing until it is heated or cooled.

Principle

Heat diffuses through the material at a rate that depends on its thermal properties. A delamination, void, crack or area of wall thinning interrupts or delays that flow. On the surface, these appear as areas that heat up or cool down at a different rate from the sound material.

Stimulus sources

  • Flash or halogen lamps.
  • Hot or cold air, or a liquid.
  • Electromagnetic induction in conductive materials.
  • Ultrasound, which produces frictional heating in closed cracks.
  • Laser, for small areas.

Main modes

  1. Pulsed: a brief pulse of energy and recording of the cooling. Shallow defects appear first and deeper ones later.
  2. Modulated (lock-in): the stimulus varies periodically and the response is analyzed at the same frequency, which improves sensitivity and reduces the effect of uneven emissivity.
  3. Step: constant heating for a period of time and analysis of how the temperature evolves.

What an engineer sees in practice

A sequence of images, not just one, processed to bring out contrasts. The depth at which a defect can be detected depends on the observation time and the thermal diffusivity of the material. The deeper the defect, the later it appears and the lower its contrast.

When it does not apply

Highly conductive materials, such as thick metals, dissipate heat quickly and make it difficult to detect deep defects. Preparing the test and choosing the stimulus require knowledge of the material and the geometry. If the stimulus involves high-power energy, the work must be done by qualified personnel.