Focus is part of the measurement
In a photograph, being out of focus only reduces sharpness. In thermography it also alters the number. An out-of-focus object spreads over neighboring pixels, and each pixel receives radiation from both the object and the background. If the object is small and hotter than its surroundings, the maximum temperature reading falls; if it is colder, the reading rises.
How to do it
- Aim at the component to be measured, not at a nearby wall.
- Adjust the focus until edges and small details, such as screws, labels or connector outlines, appear well defined.
- If the camera has autofocus or a distance meter, check the result on the screen: they can focus on the background.
- Refocus each time the distance or the object changes.
- Take the image without moving; movement during capture also causes blurring.
Special considerations
- Focus is physical, in the optics. Digital zoom enlarges the image but does not recover information that was not captured.
- Fixed-focus lenses work well within a distance range; outside it, it is advisable to move closer.
- A camera that goes out of focus because its temperature changed quickly, for example when moving from the cold outdoors to a hot room, needs time to stabilize.
- You cannot focus through ordinary glass, which is opaque to thermal infrared.
What an engineer sees in practice
An anomaly that looks soft and low in temperature in one image, and that turns out to be intense and localized in another taken with good focus. That is why sharpness must be checked before an anomaly is dismissed. Correct focus does not correct the effect of a small object or of excessive distance relative to the instantaneous field of view; those are separate factors.