What causes a circuit board to delaminate after humidity exposure?

Delamination occurs because the laminate absorbs moisture and, when it is heated, steam and stresses separate the layers, especially if the bond between resin and reinforcement was already weak.

What delamination is

In a printed circuit board, the layers of fiber-reinforced resin and the copper foils are held together by adhesion. Delamination is the separation of those layers, seen as blisters, white spots under the solder mask or swollen areas. It compromises the insulation and the integrity of the vias.

The role of water

Epoxy resins absorb moisture from the environment. The absorbed water lodges in the resin and at the interface with the fibers. This water swells the material slightly, reduces adhesion at the interfaces and lowers the effective glass transition temperature. The longer the exposure and the higher the humidity, the greater the moisture content.

The trigger: heat

Delamination usually shows up when a moist board is heated rapidly, for example during reflow soldering. The water vaporizes inside the laminate, generates internal pressure and separates the layers where adhesion is lowest. It is the same principle behind the “popcorn effect” in plastic integrated circuit packages.

What promotes it

  • Poor adhesion due to contamination, inadequate surface treatment or incomplete cure.
  • Expansion differences between layers and copper, which generate shear stresses during cycling.
  • High moisture absorption of the resin, or no prior drying.
  • Repeated thermal cycles after humidity exposure.
  • Designs with uneven copper that produce asymmetries on heating.

How it is detected

Visual and microscopic inspection for blisters, cross-sections to observe the separation, and acoustic microscopy to see internal defects without destroying the part. It can also appear as a drop in insulation or as failures in vias.

How to prevent it

Storage is controlled and the board is dried before thermal processes, a low-absorption laminate is chosen, lamination process quality is maintained and the thermal profile is limited. Drying criteria and maximum exposure times must be defined based on the material and the specification.