What the IP code is
IP stands for ingress protection. IEC 60529 defines a designation system that indicates the extent to which an enclosure, such as a housing or an electrical cabinet, protects against the penetration of solid bodies and water, and against access to hazardous parts by hand or with tools.
How it is structured
The code consists of the letters IP followed by two characteristic numerals and, optionally, additional and supplementary letters.
- First numeral: protection against solids and against access to hazardous parts. It increases with the fineness of the object kept out, up to dust.
- Second numeral: protection against water, from vertical drops to jets and various types of immersion.
- Additional letter: indicates the degree of protection of persons against access to hazardous parts when it is higher than that expressed by the first numeral.
- Supplementary letter: complementary information, such as whether the test was carried out with the equipment in motion.
When a numeral is not specified it is replaced by an X, which means it has not been classified.
What it does not classify
The code does not cover corrosion, explosive atmospheres, radiation, condensed moisture, impact damage or temperature. Nor does it guarantee that the product will work properly after a heat and cold cycle, because seals degrade. The water numerals are not cumulative in every case: a part with protection against immersion is not automatically suitable for high-pressure jets, and the definition of each numeral must be consulted.
What the engineer sees
The rating is obtained through tests under defined conditions: access probes, dust chambers, dripping, rain, jets and immersion, with the equipment in a specified condition. The result is declared with the designation and holds as long as the product does not change in its gaskets, cable entries or connectors. Any design modification can invalidate the rating.
How to use it
When specifying a product, it is advisable to describe the real environment and translate it into a code, rather than choosing the highest one. For details of each numeral and the procedures, the current edition of the standard must be consulted.