How a mechanical shock test is performed

The sample is subjected to a brief acceleration impulse with a defined pulse shape, amplitude and duration, applied in specified directions, and is then checked, or monitored during the event, for damage or loss of function.

What a shock is

A shock is a sudden, short input of energy: an impact, a drop, a detonation or the violent closing of a mechanism. Unlike vibration, which repeats over a long time, a shock occurs once or a few times and is characterized by its peak acceleration, its duration and the shape of the pulse.

Test parameters

  • Pulse shape: for example, half-sine, sawtooth or trapezoidal.
  • Amplitude: the peak acceleration.
  • Duration: the pulse time.
  • Directions and number of shocks: the axes and senses the procedure covers.

Common equipment

A shock machine drops a table onto a pulse programmer, a deformable element that determines the shape and duration of the pulse. Electrodynamic shakers are also used for controlled pulses, as are pneumatic tables. Control accelerometers measure the actual pulse on the table, which must stay within the tolerances of the specified shape.

Sequence

  1. Attach the sample with a rigid fixture that does not distort the pulse.
  2. Verify the pulse with a trial sample or an equivalent mass.
  3. Apply the shocks on each axis and in each direction.
  4. Inspect and test operation and, if necessary, monitor it during the event.

What the engineer sees

Shock failures differ from vibration failures: large components that break loose, solder joints that fracture in a single event, connectors that unseat, relays that change state or contacts that bounce during the pulse. Momentary functional losses during the event are recorded with a system that captures brief events.

How to interpret the result

An intact sample is not enough to pass: if the product must keep operating during the shock, the signal has to be monitored. The pulse values come from the test standard or the product specification and must not be assumed.