Two types of excitation
Sinusoidal vibration applies a single frequency at any instant, either fixed or sweeping across a range. It is useful for finding resonances and for simulating periodic sources, such as a motor. Random vibration applies a broad band of frequencies at once, described by a power spectral density, and more closely resembles the real environment of transport or vehicles, where the excitation is not periodic.
Basic equipment
- Shaker: electrodynamic in most cases, it converts an electrical signal into force.
- Amplifier and controller: the controller adjusts the excitation based on the reading from a control accelerometer.
- Fixture: joins the sample to the shaker and must transmit the motion without amplifying or damping it within the test range.
- Response accelerometers on the sample.
General sequence
- Measure the initial behavior with a low-amplitude sweep to locate the resonances.
- Apply the test level and duration, on each axis the procedure defines.
- Repeat the low-amplitude sweep at the end and compare the resonances: a shift indicates damage or loosening.
- Verify function and carry out a visual inspection.
What the engineer sees
The results include response curves with peaks at the resonant frequencies, where the sample amplifies the motion. Failures tend to appear at those frequencies: chafing cables, fatiguing solder joints, loosening screws. The fixture may have its own resonances that confuse the analysis, so it is characterized beforehand.
How to choose
Levels, frequencies and time are not improvised: they come from the standard, from the product specification or from measurements of the real environment. Random testing is usually more representative for fatigue, while sinusoidal testing is more precise for characterizing resonances.