How water splash resistance is tested

The enclosure is sprayed with water from several directions, using a device and flow rate set by the standard, for a defined time, and it is then checked for water ingress and for continued operation of the equipment.

What it simulates

The test reproduces the equipment’s contact with projected water, such as rain, splashes or cleaning, to confirm that its seals, gaskets and openings prevent water from entering in harmful quantities. It differs from immersion, where the equipment is under water, and from jet exposure, where the water pressure is higher.

How it is performed

  • Spray device: this can be an oscillating tube with holes, a hand-held nozzle or a fixed device, depending on the severity level of the test.
  • Angles of incidence: water is applied from several directions to find the weakest point of the enclosure.
  • Flow rate and duration: these parameters are set by the standard; they are controlled and recorded.
  • Equipment condition: it is tested with its cables, connectors and covers installed as in use, and it may be off or energized depending on the procedure.

What happens afterward

  1. The outside is dried carefully, without drying the inside.
  2. The equipment is opened and checked for moisture, droplets or stains.
  3. The point of entry, if any, is located.
  4. Operation is verified and, on electrical equipment, the electrical safety of the insulation.

What the engineer sees

The most frequent entry points are poorly seated gaskets, loose fasteners, unsealed cable entries, unsuitable breather membranes and cracks in the housing. A piece of equipment may pass with water sprayed from above and fail from a low angle, so a variety of angles is essential.

How it is classified

The second digit of the IP code classifies protection against water. The exact conditions for each level are in the IP code standard, which should be consulted in its current edition. Before applying water to live equipment, the electrical hazards must be reviewed, and those tests are performed by qualified personnel.