How a dry heat test is performed

The sample is brought to a high temperature in a chamber with low-humidity air, held until its interior stabilizes, and checked for condition and operation, either during exposure or afterward.

What the test seeks

Dry heat evaluates how well materials and components withstand high temperature without humidity being a factor. It reveals thermal degradation of plastics and adhesives, deformation, changes in electronic parameters, evaporation of lubricants and failures from excessive operating temperature.

Exposure variants

  • Storage: the sample stays off and is evaluated afterward, to see whether it survives the heat.
  • Operation: the sample runs during exposure, and its own heat dissipation adds to the heat of the chamber.
  • With or without self-dissipation: for samples that generate heat, the way air circulates changes the result.

General sequence

  1. Condition the sample and record its initial measurements.
  2. Install temperature sensors on the sample, especially at the most critical or hottest points.
  3. Place it in the chamber in a position that allows air circulation and does not obstruct the chamber airflow.
  4. Raise the temperature at the rate stated in the procedure; a slow ramp avoids overshoot and large gradients.
  5. Hold until the sample stabilizes, not just the chamber.
  6. Verify functions during exposure if it is an operational test.
  7. Return to ambient with a controlled ramp, allow recovery and repeat the measurements.

What the engineer sees

The sample temperature takes time to match that of the chamber, and in equipment that dissipates power it can locally exceed it. A component can pass at ambient temperature and fail when the surrounding air is hot, because its internal temperature exceeds its limit. After the test, look for deformation, discoloration, cracks and changes in the measurements.

How to interpret the result

The behavior is compared with the baseline and with the acceptance criteria. Temperature and duration depend on the product specification or the applicable standard. Samples containing batteries, liquids or flammable materials require additional precautions and trained personnel.