What relative humidity is and how it affects electronics

Relative humidity is the ratio between the water vapor present in the air and the maximum the air could hold at that temperature. In electronics it promotes corrosion, leakage and condensation, and its absence promotes electrostatic discharge.

What it measures

Relative humidity expresses, as a percentage, how much vapor the air contains compared with the maximum possible at its temperature. Because warm air can hold more vapor than cold air, relative humidity changes even if the amount of vapor stays the same: when a mass of air is cooled, relative humidity rises until it reaches the dew point and the vapor condenses.

How it affects equipment

  • Corrosion: a film of water adsorbed on metal surfaces enables electrochemical reactions, and ionic contaminants aggravate the effect.
  • Leakage currents: moisture reduces the surface resistance between traces, especially where there is flux residue or dirt, and can cause erratic readings in high-impedance circuits.
  • Electrochemical migration: under voltage and humidity, metal can migrate between conductors and form dendrites that cause short circuits.
  • Absorption in materials: laminates and encapsulants absorb moisture, which can damage the component during high-temperature soldering.
  • Condensation, if the surface is colder than the dew point.

The other extreme

In very dry air, insulating materials build up charge easily, and the risk of electrostatic discharge that damages sensitive components increases. For this reason, humidity control in assembly areas aims for an intermediate range, not the lowest value.

What the engineer sees

Failures that appear in the rainy season or in certain areas of the building, boards with white or greenish residue, and high-impedance sensors with offsets. These signs must be related to both the recorded humidity and the recorded temperature, not to just one of them.

How it is managed

The environment is controlled, conformal coatings or encapsulation are used, sensitive components are stored in moisture-control bags, and ventilation is designed to avoid cold surfaces. The exact conditions depend on the product and the manufacturer’s specifications.