What is a thermistor and when is it used?

A thermistor is a resistor made of semiconductor material whose resistance changes greatly with temperature; it is used when high sensitivity is needed over a relatively narrow range, as in the thermal control of electronics and batteries.

What it is

A thermistor is a temperature-sensitive resistor, normally made from metal oxides or polymers. Its name combines “thermal” and “resistor”. Unlike metals, whose resistance changes little, a thermistor changes a great deal per degree, which makes it a very sensitive sensor.

Two main types

  • NTC. Negative temperature coefficient: resistance falls as temperature rises. This is the type most used for measuring temperature.
  • PTC. Positive coefficient: resistance rises with temperature. Some types show a very sharp increase beyond a certain temperature and are used for protection, for example to limit current or protect windings.

Behavior

The relationship between resistance and temperature is strongly nonlinear. Empirical equations are used for conversion, such as the beta parameter model, which is a simple approximation over a narrow range, or the Steinhart-Hart equation, which is more accurate over a wider range. The manufacturer usually provides the coefficients or tables.

When it is used

  • Temperature control of electronics, batteries and chargers.
  • Temperature compensation in circuits.
  • Medical and household applications, where a limited range is enough.
  • Measurements with good resolution over short ranges.

Limitations

  • Nonlinearity. It requires linearization by circuit or software.
  • Limited range. Compared with RTDs and thermocouples, it works over a shorter range, especially toward high temperatures.
  • Self-heating. Because of its resistance and sensitivity, excessive measuring current heats the sensor and distorts the reading.
  • Interchangeability and stability. Certain types have more unit-to-unit spread and age more than a platinum sensor.

An example

In a battery pack, a thermistor attached to the cells makes it possible to monitor heating. There is no need to measure a wide range, but rather to detect a change in a bounded zone quickly and with good resolution, which matches the thermistor’s strengths.

When it does not apply

If a wide-range measurement, high long-term stability or maximum interchangeability is required, a platinum resistance thermometer is usually better. For high temperatures, a thermocouple.