Two different disturbances
A regulated power supply aims to deliver a constant output. But there are two main causes of variation, and they are characterized separately.
- Line regulation: variation in the output when the input changes within its range, with the load fixed.
- Load regulation: variation in the output when the load changes, normally from no load to full load, with the input fixed.
How they are expressed
They are given as an absolute voltage change, for example in millivolts, or as a percentage of the rated output. The lower the value, the better the supply regulates. It is worth reading the specification to see under what conditions it was measured, because results change as the input range, temperature or load point vary.
Relationship with output impedance
Load regulation is closely tied to output impedance: an ideal supply would have zero impedance and would not vary with current. In practice, the voltage drop across that impedance, and across the cables between supply and load, produces the variation. That is why many supplies offer remote sensing, which measures the voltage at the load and compensates for the drop in the cables.
How it is measured
- Set a reference condition and record the output with a voltmeter whose resolution is finer than the expected variation.
- Change only one variable: input or load.
- Wait for it to stabilize, since the supply heats up and the output moves slowly.
- Calculate the difference between the extreme values.
What you see in practice
Line regulation is better in linear supplies with good feedback and in well-designed switching supplies. Load regulation worsens as the current approaches the limit, and changes if the current limit activates or if the cables are long. It must not be confused with transient response, which is the behavior during the change.
Measurements on mains-powered supplies must be made by qualified personnel in accordance with the applicable regulations.