Definition
Two circuits are galvanically isolated when there is no conductive connection between them and yet one can communicate with or transfer energy to the other. Instead of wires, the information travels through a medium that does not conduct direct current: a magnetic field in a transformer, light in an optocoupler, or an electric field across a capacitive barrier.
What it is for
- Safety: an isolation barrier prevents a hazardous voltage in one circuit from reaching the operator or the low-voltage circuits connected to it.
- Breaking ground loops: if two pieces of equipment share ground through different paths, currents circulate that add noise and errors; with isolation, the common path disappears.
- Measuring at floating potentials: it allows signals at a high voltage relative to ground to be measured without the instrument being connected to that voltage.
- Protecting electronics against overvoltages and transients from the power side.
How the signal is transferred
Energy is delivered through transformer-based converters that power the isolated side. Analog signals are converted into a format that can cross the barrier, whether digitized, modulated or with linear coupling. For digital signals, optocouplers or magnetic or capacitive isolators are used.
Limits and precautions
- The barrier has a rated isolation voltage; exceeding it can break down the isolation. That specification, the continuous working voltage and the transient test voltage are different quantities.
- Some stray capacitance always remains between the two sides. High-frequency currents and fast voltage changes pass through it, which degrades the system’s common-mode rejection.
- Isolation alone does not make an installation safe; it requires proper rating of equipment, connections and procedures.
What the engineer sees
On a non-isolated oscilloscope, connecting the probe ground to a point with a potential relative to ground causes a dangerous short circuit; with an isolated channel or an isolated differential probe, the measurement can be made without that risk. In data acquisition equipment, isolated channels prevent a fault in one channel from affecting the others.
Work with hazardous voltages must be performed by qualified personnel following the applicable electrical safety regulations.