Definition
In a two-level periodic signal, the duty cycle is the time spent at the high level divided by the full period. A symmetrical square wave has a duty cycle of 50 percent. A narrow repeating pulse has a low duty cycle, and a signal that is almost always high has one close to 100 percent. It does not depend on frequency: two signals of very different frequencies can have the same duty cycle.
Why it is useful
The average value of a rectangular signal between a low level and a high level is proportional to the duty cycle. This makes it possible to control power without dissipating heat in a linear element: a load fed with pulses receives an average power that depends on the high time. This is the principle of pulse-width modulation (PWM), used in motor control, lighting dimming, switching power supplies, and generating analog signals from digital outputs with a low-pass filter.
How it is measured
- Oscilloscope: the pulse width and the period are measured at a defined threshold, normally half the amplitude, and the ratio is calculated. Many instruments provide the measurement automatically.
- Frequency or time counter: measures the positive width and the period.
- Multimeter with a duty cycle function: suitable for signals of simple shape and sufficient amplitude.
Details for interpretation
The result depends on the threshold. With slow edges or noise, changing the threshold changes the measured width. The signal must not be distorted by a poorly compensated probe or by the load. For signals with more than two levels, the concept must be defined carefully.
Relationship to other quantities
The RMS value of a pulse signal between zero and a high level depends on the square root of the duty cycle, while the average depends on it directly. That is why an averaging instrument and an RMS instrument read different things on the same signal. When generating signals with a function generator, the duty cycle is usually an adjustable parameter of the pulse or square waveform.
An example
A signal swinging between zero and five volts with a duty cycle of 20 percent has an average of one volt. If the frequency is doubled without changing the duty cycle, the average stays the same.