What Is Receiver Sensitivity?

The sensitivity of a receiver is the minimum signal level at its input at which it achieves the required reception quality, for example a given signal-to-noise ratio or error rate.

A definition with a condition

Sensitivity is not an isolated number: it always comes with a quality criterion. In an analog receiver it may be a minimum signal-to-noise ratio; in a digital one, a given bit error rate. Saying “a sensitivity of minus one hundred decibel-milliwatts” without the criterion and the bandwidth means nothing comparable.

What it depends on

The limit is set by noise. Every receiver has a noise floor made up of the thermal noise at the input and the noise added by its own circuits. Three factors determine it:

  • Bandwidth: the wider the bandwidth, the more noise power gets in, so sensitivity worsens.
  • Noise figure: it measures how much the receiver degrades the signal-to-noise ratio compared with an ideal receiver.
  • Required signal-to-noise ratio: the ratio the demodulator needs to meet the criterion; it depends on the modulation and coding.

The thermal noise available in a bandwidth of one hertz at the reference room temperature is approximately minus 174 dBm, and it grows in proportion to bandwidth. Starting from that floor, the noise figure and the required signal-to-noise ratio are added to obtain the sensitivity.

What you see in practice

When a weak signal reaches a receiver, the link works down to a certain level and then suddenly degrades: errors, audio stuttering or loss of synchronization appear. The level at which this occurs is, in practical terms, the sensitivity. It is measured with a signal generator of calibrated level, reducing the amplitude until the established criterion is crossed.

Sensitivity is not range

Range also depends on transmitter power, antenna gains, cable losses and propagation. Better sensitivity contributes, but does not determine it alone. In addition, ambient noise and interference can raise the effective floor above the thermal floor, so that the receiver never reaches its nominal sensitivity in the field.

Common mistakes

  • Comparing the sensitivities of receivers with different bandwidths or quality criteria.
  • Forgetting the cable or connector losses between the generator and the receiver input when measuring.
  • Confusing sensitivity with selectivity, which is the ability to reject signals from neighboring channels.
  • Assuming that a more negative number always means “better” without considering the measurement condition.