What changes when going from module to product
A module is presented as an almost finished solution: it already includes the radio, filters and firmware. But its final performance depends on the environment where it is installed. A module on a development board with a reference antenna can achieve an excellent link and then behave badly inside a housing with batteries, a display and cables.
Antenna
This is the most important factor. Printed or chip antennas require a ground plane and a keep-out area free of copper and components, both defined by the manufacturer; if that area is encroached on, the antenna detunes. Housings, batteries, cables and the user’s hand change the resonant frequency and absorb energy. An external antenna gives more freedom of placement, but adds lossy connectors and cables.
Power supply and noise
- Transmission causes current peaks; a weak supply or insufficient decoupling produces voltage drops and resets.
- Switching noise from regulators and digital clocks can raise the receiver’s noise floor and reduce sensitivity.
- Fast lines running close to the antenna or the RF cable couple into it.
Regulation
A module with modular certification makes type approval of the product easier, but the certification is usually limited to certain antennas, mounting conditions and configurations. Changing the antenna or its gain, or modifying the power parameters, may require additional evaluation. In addition, the finished product must meet electromagnetic compatibility and safety requirements in its own right. Requirements depend on the country and must be checked with the competent authority.
Tests
- Conducted power and spectrum at the module connector, to confirm that the configuration is as expected.
- Range and signal strength tests with the product closed and in real use.
- Radiated tests of total power and sensitivity, which include the effect of the antenna and the housing.
- Coexistence tests with other radios in the same product.
Common mistakes
- Leaving antenna selection until the end.
- Placing metal parts or batteries over the antenna area.
- Evaluating only on the bench, without the housing.
- Ignoring the firmware: power management and retries influence the experience as much as the radio does.