24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Why Does Speed Drop on a Saturated Network?

On a saturated wireless network speed drops because the channel is a shared resource: each transmission takes up airtime, and with more users, more collisions and more retransmissions, less useful time is left for each one.

Speed is airtime

The speed a wireless link advertises is the maximum rate of the modulation, not what each user receives. All the devices on a channel take turns to talk, and actual throughput is what fits into that shared time, after subtracting headers, acknowledgments and waits. As users are added, the same time is divided among more of them.

Why it falls more than expected

  • Contention and collisions: devices listen before transmitting and wait a random time; with many competitors, more frames collide and must be repeated.
  • Slow clients: a device with a weak signal transmits with low-order modulation and occupies the channel much longer for the same data, taking time away from everyone else.
  • Small, frequent traffic: many short packets have a fixed channel access cost that weighs more than the data.
  • Hidden nodes: two stations that cannot hear each other transmit at the same time toward the same access point and collide.
  • External interference: other networks or other sources on the same channel increase occupancy.
  • Wired bottleneck: sometimes the limit is in the uplink and not in the air.

What is observed

The typical symptom is good signal strength with poor throughput, variable latency and packet loss during peak hours. Access points report high channel utilization, many retransmissions and low negotiated rates on some clients.

How to diagnose

Measure channel utilization and the proportion of retransmissions, check which clients are using the lowest rates and compare with a throughput test on the wired segment to separate an airtime limit from a network limit. A spectrum analyzer helps to distinguish your own load from outside interference.

What to check first

Before changing equipment, check the number of clients per access point, the channel plan, the power (sometimes too high, which causes more clients to compete) and the possibility of disabling very low rates to push out the slowest clients. Adding access points on different channels spreads the load, while adding them on the same channel can make it worse.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer