24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

How is the coexistence of multiple radios in one device tested?

The coexistence of multiple radios in one device is tested by operating the radios simultaneously and comparing the performance of each with its performance in isolation, to detect desensitization, mutual interference and loss of throughput.

Why there is a problem

When two radios share an enclosure, their antennas are very close together and the signal from one transmitter reaches the neighboring receiver at an enormous level compared with the weak signal it is trying to receive. Even if they operate at different frequencies, they can harm each other through several mechanisms:

  • Blocking or saturation: the neighbor’s strong signal reduces the receiver’s gain.
  • Transmitter out-of-band noise: spurious emissions and broadband noise fall within the receiver’s band.
  • Harmonics and intermodulation products: their frequency coincides with the band of another radio.
  • Clock and digital line interference: the equipment’s internal noise raises the receiver’s noise floor.
  • Access coordination: radios in the same band compete for the medium and need arbitration.

How it is tested

  1. List the combinations. Which radios can run at the same time in real use, on which channels and at what powers. Worst cases are prioritized, such as contiguous channels or coinciding harmonics.
  2. Establish a baseline. Each radio is measured alone: sensitivity, data throughput, modulation quality.
  3. Activate the others. The measurement is repeated with the other radios transmitting in the most demanding mode, and the results are compared.
  4. Analyze the degradation. Sensitivity loss is expressed as the increase in the required minimum level relative to the baseline, and throughput as the drop in data rate or the increase in retries.
  5. Repeat by coupling path. Conducted by cable to isolate the electronic effect, and over the air with the real antennas to include physical coupling.

How to interpret the result

Degradation only when the neighbor transmits suggests blocking or transmitter noise. If it occurs with the neighbor merely powered on but not transmitting, it points to internal digital noise. Solutions include filtering, antenna separation or isolation, channel reassignment and time coordination of access.

When it should be reviewed again

Any change of antenna, shielding, power-altering firmware or channel selection can affect coexistence, so testing just once is not enough.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer