What it is and what it is not
Sensitivity is not an absolute level of “what the receiver hears” but the input level at which it meets a quality criterion. Without a criterion there is no sensitivity: the same receiver has different values if a low error rate or a more permissive one is required. That is why every sensitivity figure must be accompanied by the criterion, the modulation and the bandwidth with which it was measured.
Method
- Define the criterion. For example, a specific bit or packet error rate, or a minimum signal-to-noise ratio after demodulation.
- Prepare the signal. A signal generator delivers the modulated signal in the system’s own format, at a defined frequency and modulation. It is connected to the receiver by cable, to exclude external interference, or inside a shielded chamber if testing over the air.
- Calibrate the path. The losses of cables, attenuators and adapters are measured and subtracted, so that the stated level is the one actually reaching the receiver input.
- Reduce the level. Starting from a level with ample quality, it is lowered in steps until the criterion is barely met. Near the limit the error rate changes quickly, so the final steps must be fine.
- Record. The level at the limit is noted, along with the configuration and conditions.
What it depends on
- Thermal noise, which grows with bandwidth.
- The noise figure of the receiver.
- The signal-to-noise ratio required by the modulation scheme.
- Coding and implementation margins.
How to interpret the result
Better sensitivity, that is, a lower minimum level, indicates a receiver able to operate with weaker signals, but it does not guarantee good behavior with strong signals or under interference. Those capabilities are measured separately, with selectivity, blocking and intermodulation tests.
A result that worsens when other circuits in the equipment are active suggests desensitization by self-generated noise, a common issue in equipment with several radios or with digital electronics close to the antennas.