How is a point-to-point radio link validated?

Validating a point-to-point radio link means confirming that what is measured matches what was calculated: line of sight and clearance, received signal level, fade margin, signal quality and absence of interference.

What validating means

The link budget predicts how much power will reach the receiver from the transmitted power, the antenna gains, the cable losses and the path loss. Validating means checking that prediction against reality and confirming that there is enough margin for the link to work even when conditions worsen.

Validation steps

  1. Review the path. Beyond line of sight, propagation needs a clear ellipsoid-shaped zone around it, called the Fresnel zone. Obstacles inside it degrade the signal even if they do not block the line of sight.
  2. Install and align the antennas. Each antenna is pointed for maximum signal, with attention to polarization. A small misalignment in high-gain antennas produces a significant loss because their beam is narrow.
  3. Check the equipment. Correct transmit power and frequency, cables and connectors free of abnormal losses, acceptable standing wave ratio.
  4. Measure the received signal. The level is compared with the calculated one. A large difference points to an alignment problem, a cable problem, an obstruction or a wrong figure entered in the calculation.
  5. Evaluate the margin. It is the difference between the received level and the required sensitivity. It must cover fading, rain at high frequencies and component aging.
  6. Measure quality. Error rate, error vector magnitude or packet loss over a representative period, not just an instant.
  7. Look for interference. A spectrum survey at the working frequency and on neighboring channels.

What is seen in practice

A correct level with high errors points to interference or multipath reflections. A low level that varies with the weather suggests insufficient margin. A level that changes over the course of the day may indicate atmospheric refraction or tower movement.

An example

If the calculation predicts a certain level and much less is measured, the cable and connectors should be checked first, then the alignment and finally the path clearance. The final values are documented as a baseline for future comparison.

Work on towers and near transmitting antennas must be done only by qualified personnel, in accordance with the applicable safety regulations.