24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What is modulation and why is it needed?

Modulation means changing a characteristic of a carrier (amplitude, frequency or phase) with the information to be sent; it is needed because the original signal cannot be transmitted effectively or share the spectrum without it.

The problem it solves

Information, whether voice, data or video, occupies low frequencies, known as baseband. Transmitting it directly over the air would require antennas of impractical size, because an efficient antenna has dimensions comparable to the wavelength. In addition, all users would share the same region of the spectrum and mix with one another. Modulation moves the information onto a carrier of much higher frequency, which allows antennas of reasonable size and the assignment of different channels to different services.

What is changed

  • Amplitude: the information changes the strength of the carrier. It is simple but sensitive to noise, which tends to affect amplitude.
  • Frequency: the carrier shifts around its center value. It withstands amplitude noise better, at the cost of more bandwidth.
  • Phase: the position of the wave in time is changed. It is the basis of many digital schemes.

Digital schemes combine these parameters to represent groups of bits with symbols. A symbol can carry several bits if there are enough distinguishable states, which makes it possible to increase the data rate without a proportional increase in bandwidth.

The underlying trade-off

More states per symbol means more information per unit of bandwidth, but the states end up closer together and the receiver needs a higher signal-to-noise ratio to tell them apart without errors. That is why real systems adapt the scheme to the quality of the link.

What the engineer sees

On a spectrum analyzer, an unmodulated carrier is a narrow line; when it is modulated, sidebands appear whose width depends on the data rate and the scheme. On a vector analyzer, the constellation can be observed, where each point is a symbol. Scattered points indicate noise, distortion or phase errors.

To complete the picture

At the receiver, demodulation does the reverse and recovers the information. A good part of link design consists of choosing a modulation consistent with the available bandwidth, the power and the expected channel noise.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer