Definition and difference from interference
In electromagnetic compatibility terminology, the disturbance is the cause: an unwanted field, current or voltage. Interference is the result, that is, the degraded performance of the receiving equipment. A disturbance can exist without producing interference if the equipment is immune enough. That is why disturbances are measured as emissions and the immunity of the equipment is verified.
Origins
- Natural: lightning, electrostatic discharge, cosmic and atmospheric noise.
- Intentional man-made: radio transmitters, radar, communications.
- Unintentional man-made: converter switching, motors, relays, digital clocks, electric arcs.
How they are classified
By propagation, they are divided into conducted disturbances, which travel along power and signal cables, and radiated disturbances, which travel through space as a field. By duration, they are continuous, transient or impulsive. By spectrum, they are narrowband, like a carrier, or broadband, like switching noise.
How they reach the equipment
To produce an effect they need a coupling path. Coupling can be through a common impedance, when two circuits share a return; capacitive, through the electric field between conductors; inductive, through the magnetic field between loops; or radiated, when a cable or trace acts as a receiving antenna. Understanding which mechanism dominates decides the countermeasure: filter, shield, separate or change the layout.
An example
A brushed motor generates sparks, which are a broadband disturbance. If a nearby radio receiver picks up noise, that noise is the interference. Action can be taken at the source with filters on the motor, along the path by moving cables away or shielding them, or at the receiver by improving its immunity. The most efficient solution is usually as close to the source as possible.
Why precise terminology matters
In test reports, saying that a piece of equipment “generates interference” when an emission is being measured is imprecise. The correct approach is to speak of disturbance levels and compare them with limits that already take the risk of interference into account.