How is an emission source located with near-field probes?

A near-field probe connected to a spectrum analyzer is swept over the circuit, and the rise in level at the problem frequency is followed until the point of maximum level is found. That point marks the source or the element radiating it.

Principle

Very close to a source, the field falls off rapidly with distance. A small probe brought near traces, components or cables detects that localized field and makes it possible to pinpoint where the energy is generated or radiated. Probes do not measure absolute levels that can be compared with a limit; they serve to compare positions and before/after results of a modification.

Probe types

  • Magnetic field (loop): responds to changing current. Useful for traces, inductors, transformers and cables carrying high current.
  • Electric field (monopole or tip): responds to changing voltage. Useful for high-impedance nodes, heat sinks and switches.
  • Current clamp: for measuring common-mode current on cables.

Procedure

  1. Identify in the emissions measurement the frequencies that exceed or approach the limit.
  2. Connect the probe to a spectrum analyzer, with a preamplifier if the level is low, and set the frequency of interest.
  3. Move across the board at a short distance and with constant orientation, watching where the level rises.
  4. Repeat with the probe over cables, connectors, slots and enclosure seams.
  5. Determine whether the maximum is on a circuit (clock, switching power supply) or on a radiating element (cable, heat sink).
  6. Apply a modification and measure again at the same position.

How to interpret what you see

If the level peaks at an oscillator and its harmonics, the source is the clock. If it grows as the probe approaches a cable leaving the equipment, the disturbance is coupling onto the cable and the cable is acting as an antenna; the treatment is filtering or shielding, not circuit redesign. If it changes when a cable is moved, the problem depends on the layout.

Limits of the method

The probe disturbs the circuit slightly, and its position and orientation change the reading. A strong near-field source does not always dominate the radiated emission at a distance, because coupling to the outside depends on which structure acts as an antenna. For this reason, the method is complemented by measurements on cables and by the formal test.