Electromagnetic compatibility is the ability of equipment or a system to function satisfactorily in its electromagnetic environment without producing intolerable disturbances for others or being affected by those in its environment.

Definition and two sides

Electromagnetic compatibility, or EMC, involves two requirements that must be met at the same time. The equipment must not emit disturbances that affect other equipment, and it must tolerate the disturbances present in its environment. The first side is called emission and the second, immunity. Electromagnetic interference, or EMI, is the phenomenon that occurs when either of them fails.

The three-element model

Every EMC problem can be analyzed with three elements: a disturbance source, a coupling path and a susceptible victim. If any of the three is eliminated or weakened, the problem disappears.

  • Source: circuits with fast current or voltage changes, digital clocks, switching power supplies, motors, electrostatic discharges, radio transmitters.
  • Coupling: conducted through cables and grounds, or radiated by fields. In the near field it can be capacitive or inductive.
  • Victim: low-level analog circuits, receivers, digital inputs and sensors.

How it is approached in engineering

  1. Design with good practices from the start: ground layout, short current returns, power supply decoupling, control of transition times and trace routing.
  2. Apply shielding and filtering on cables and power inputs.
  3. Evaluate with emission and immunity tests, according to the product standards applicable to the equipment category.
  4. Correct iteratively: a pre-compliance measurement helps locate sources before the formal test.

What the engineer sees in practice

Emission tests show a spectrum with peaks associated with clocks and their harmonics, and each peak is compared with the limit. In immunity tests, the degradations or failures of the equipment are observed when a defined disturbance is applied to it. Equipment that passes on a bench can fail once installed, because the cables and grounds of the real installation form new coupling paths.

Why it is not solved at the end

Late changes tend to be costly and limited. It is more efficient to think about EMC from the architecture stage than to add patches at the end.