Where it appears
The radiation pattern of a directional antenna has a main lobe, where most of the energy is concentrated, and other smaller lobes separated by minima. The minor lobes that are neither the main lobe nor the back lobe are called side lobes. The lobe closest to the main lobe is usually the highest, and its relative level is expressed in decibels below the maximum.
Where they come from
A side lobe results from the way current is distributed across the aperture or structure of the antenna. A uniform distribution gives the narrowest beam but relatively high side lobes. Tapering the intensity toward the edges of the aperture lowers the side lobes at the cost of widening the beam somewhat and losing a little gain. Mechanical defects, supports and aperture blockage also raise the side lobes.
What effect they have on a system
- Interference: a receiving antenna picks up unwanted signals through its side lobes, and a transmitting antenna radiates energy toward sectors where it should not.
- Spectrum sharing: coordination between links depends on the level of radiation outside the beam.
- Direction measurements: when searching for a source, a side lobe can produce a false maximum.
- Emissions testing: the off-axis response of the measuring antenna determines how much the surroundings affect the result.
How they are observed and controlled
They can be seen directly in a pattern cut, on a logarithmic scale, as secondary peaks on both sides of the main lobe. To reduce them, designers use amplitude distributions that taper toward the edges in arrays, well-designed reflectors, structures with smoothed edges and absorbers on supports. A pattern measured in a chamber with residual reflections can show side lobes that are actually echoes.
An important nuance
Side lobe level cannot be interpreted from a number alone. What matters is the direction in which the lobes lie, because a high lobe in a direction with no sources or receivers is harmless, and a low one pointing at an interfering source can be a problem.