Why Is Coverage Lost After a Cable Change?

When coverage is lost after a cable change, the cause is almost always higher attenuation, faulty connectors or adapters, an impedance mismatch or a cable type unsuited to the frequency and length, and not the antenna itself.

Where to look

When coverage worsens right after a cable is changed, the transmission line is the first suspect. Every cable introduces losses that grow with length and frequency, and any deviation from the original cable translates into less power at the antenna and less sensitivity on receive.

Most likely causes

  • Higher attenuation: a thinner, longer or lower-quality cable loses more power. At high frequencies the difference becomes more pronounced.
  • Connectors or adapters: each one adds a small loss and a possible reflection. A badly assembled connector can add a much greater loss.
  • Impedance mismatch: using a cable with a different characteristic impedance causes reflections.
  • Damaged cable: tight bends or crushing deform the coax and change its impedance.
  • Moisture: poor sealing lets water in, with attenuation increasing over time.

How to verify it

  1. With a cable and antenna analyzer, measure the return loss of the line connected to the antenna and, with the end open or shorted, the insertion loss of the cable.
  2. Compare the measured attenuation with the value for that cable type and length in the band of use.
  3. Use the distance-to-fault function to locate reflections.
  4. Confirm that the antenna and the equipment are in the same configuration as before the change.

How to interpret the result

Good return loss with high attenuation indicates that the cable is the problem even though it is well matched: the signal is attenuated before it reaches the antenna. Poor return loss indicates a reflection, and distance to fault shows where it is.

When the cause is not the cable

If the line measures well, check whether the change altered the height, orientation or position of the antenna, or whether the equipment was left configured with a different output power.