What happens at the connector
A coaxial line maintains a constant impedance thanks to the ratio between its diameters and to the dielectric. A badly crimped connector, with the dielectric trimmed incorrectly, the center conductor misaligned or poor contact with the shield locally alters that geometry. Where the impedance changes, part of the wave is reflected and the rest continues with additional loss.
How it shows up in the measurement
- Return loss: the frequency sweep shows a worse value than expected, with periodic ripple. Its period in frequency is related to the distance between the discontinuity and the other end of the line.
- Distance to fault: when the measurement is converted to the distance domain, a peak appears at the position of the connector. This distinguishes a connector defect from one in the cable or the antenna.
- Instability: the reading changes when the connector is moved or touched, which indicates an intermittent contact.
Frequent installation causes
- An uneven cable cut, or burrs on the shield touching the center conductor.
- A center conductor that is too long or too short, or soldered with excess material.
- A connector of the wrong type or size for that cable.
- Insufficient tightening, or overtightening that deforms the dielectric.
- Inadequate sealing that lets water in.
What to check first
Before replacing the cable, repeat the measurement with a known adapter or jumper to confirm that the reflection does not come from the test cable or from an incorrect calibration. Then locate the peak and inspect the corresponding connector. After correcting it, measure again and compare with the previous reading.
What it means for the system
Besides the loss of radiated power, the reflection travels back to the transmitter, where it reduces the amplifier’s safety margin. That is why the line is verified before power equipment is put into operation.