The mechanism
A transmission line delivers all its power to the load only if the load impedance matches that of the line. When it does not match, part of the wave is reflected. The reflected wave travels back along the cable and combines with the incident wave, forming standing waves. The reflection coefficient and the standing wave ratio (SWR) express how much is reflected: an SWR of one means a perfect match, and increasing values indicate more reflection.
Why this damages the output stage
- Power dissipated in the amplifier: the reflected energy does not disappear; it returns to the final stage, which has to dissipate more heat than intended.
- Abnormal voltage and current: depending on the electrical length of the line, the amplifier sees a load impedance different from the nominal value, with voltage or current peaks in the transistors.
- Operation outside the safe area: power devices have simultaneous voltage, current and temperature limits, and a poorly matched load can exceed them.
What causes it in the field
- A loose or corroded connector, or one with water inside.
- A damaged or crushed cable, or one with an excessive bend.
- An antenna that is open, shorted or poorly installed, or covered with ice or dirt.
- An antenna used outside its design band.
- Transmitting with no load connected.
Protection circuits and their limits
Many transmitters measure reflected power and reduce their output power or shut down when the SWR is high. That protection helps, but it is not infallible: it can react too late to a transient, and in some equipment it only reduces the stress rather than eliminating it. Relying on it as the only control is a common mistake.
How it is diagnosed
A cable and antenna analyzer injects a low-power signal and shows return loss or SWR as a function of frequency. Measuring with the transmitter off and the antenna disconnected allows the system to be checked without risk to the equipment. If a fault location mode is available, it indicates the approximate distance to the reflection point, which separates a connector fault from an antenna fault.
Common mistakes
- Measuring SWR only at the operating frequency and not across the full band.
- Calibrating the analyzer without including the test cables that will be used.
- Taking a low SWR value to mean a healthy system, when losses in a badly degraded cable also mask it.
Any work on towers or with power transmitters must be done by qualified personnel, following the safety regulations applicable to work at height and radio-frequency exposure.