General scope
IEEE 149 is a guide to procedures for testing antennas. It is complemented by IEEE 145, which defines the terms. While the latter sets the meaning of gain or polarization, IEEE 149 explains how to measure those characteristics and what precautions to take so that the result is reliable.
What kind of content it includes
- Test ranges: description of the facilities where measurements are made, such as outdoor ranges, chambers and compact ranges, and the conditions they must meet.
- Far field and distance: criteria for deciding the separation between antennas, so that the incident wave can be treated as a plane wave at the aperture under test.
- Radiation pattern: how to record level as a function of angle and how to present the cuts.
- Gain and directivity: methods based on comparison with a standard antenna, and absolute methods.
- Polarization: how to characterize it and present its results.
- Impedance: measurements of the reflection coefficient and matching.
Why the distinction between methods matters
The comparison method requires an antenna of known gain, and its accuracy depends on that of the standard. Absolute methods, such as the three-antenna method, derive gain from the physics of the link. The choice affects the uncertainty of the result.
How it is used in practice
- Choose the type of range according to the size of the antenna and the frequency.
- Verify the quality of the range, for example with the quiet zone, before measuring.
- Document the setup, the corrections applied and the sources of uncertainty.
What to consider when citing it
A report must state which method in the guide was applied and which edition was consulted. Since procedures and recommendations can be updated, the current edition must be consulted before planning or reporting a test.